Overview
Thermal insulation, acoustic insulation and fire protection in building construction applications.
Stats & Charts
Thermal insulation, acoustic insulation and fire protection in building construction applications.
| material properties | symbol | value | description | standard |
| MATERIAL | -- | -- | GRANULATED NON-COMSUTIBLE STONEWOOL | |
| TYPE OF MATERIAL | -- | -- | BLOWING WOOL | -- |
| APPLICATION | -- | -- | THE INSTALLATION IS PERFORMED BY BLOWING WOOL | -- |
| AVERAGE DENSITY(UNREGULAR SHAPE) | ** | KG/M3 | ≈ 36,80 Kg/m3 | -- |
| AVERAGE DENSITY(REGULAR SHAPE) | ** | KG/M3 | ≈ 40,00 Kg/m3 | -- |
| WEİGHT (BAG:20/1) | -- | KG/M3 | 30 | -- |
| PRODUCT PACKING SYSTEM | -- | -- | Plastic Bag On Wooden Pallet / 20 Kg Pe Packing ( Approx... ) | -- |
| FIRE CASS REACTION | -- | -- | A1 | TS EN 13501-1 |
| THERMAL CONDUCTIVITY VALUED DECLARED 10°C | ID*-* | W/mK | 0.037 | TS EN 12667 TS EN 12939 |
| MAXIMUM SERVICE TEMPERATURE | -- | mk | 700 | TS EN 14706 |
| COMPRESSIVE STRENGHT | δ10 | kPa | Not Reqired | -- |
| COVERING | μ | -- | Not Reqired | DIN 18165 |
| WATER ABSORPTION | - | %v/v | ≤ 1 Kg/m2 | ASTM C 272 |
| NOMINAL VAPOUR DIFFUSION RESISTANCE FACTOR | MU | -- | Mu1 ( ≈ 1,0) | -- |
| SETTLEMENT | S | -- | S2 | -- |
| CONSUMPTION PER 1M2 (FOR DENSITY ≈ 32,8 KG/M3) |
| THICKNESS | RESISTANCE RD | WEIGHT OF GRANULATE | NO OF BAGS |
| MM | M2K/W | KG | PCS |
| 50 | 1,3 | 1,44 | 0,07 |
| 100 | 2,6 | 2,88 | 0,14 |
| 150 | 3,95 | 4,32 | 0,22 |
| 200 | 5,25 | 5,76 | 0,29 |
| 250 | 6,55 | 7,2 | 0,36 |