SQUARE CEILING LAMELLA

Homepage / Products / SQUARE CEILING LAMELLA

Overview Installation wool is used as the reverse ceiling tile. Thermal insulation of ceiling covering of garages and other indoor areas in new and old buildings.

Stats & Charts Installation wool is used as the reverse ceiling tile. Thermal insulation of ceiling covering of garages and other indoor areas in new and old buildings.
Material PropertiesDescriptionStandard
Material Stonewool TS EN 14303:2009+A1 2013
Type Of Material SQUARE CEILING LAMELLA-
Application * Installation wool is used as the reverse ceiling tile.
* Thermal insulation of ceiling covering of garages and other indoor areas in new and old buildings.
-
Product Packing System Each slop is put into carton according to the thickness and packings are put on wooden pallets then packed with strech film, labels are available on the packages.-
StandardTechnical Parameters Symbol Value Report Standard
Density +/-%3 kg/m3 90 -
Thermal Conductivity Declared (10 °C) λD 0,035 W/m.K - TS EN 12667/12939
Reaction to Fire - A1 - TS EN 13501-1:2007+A1:2009
Thickness Accuracy Class Tolerance - T3 - EN 13162:2012+A1:2015( EN 823 )
Long-Term Absorption WL(P) max. 3,0 kg/m2 ≤3EN 13162:2012+A1:2015( EN 12087)
Short-Term Absorption WS max. 1,0 kg/m2 ≤3 EN 13162:2012+A1:2015( EN 1609 )
Vapor Permeability μ max. 1 ≤1 TS EN 12086:2002
Tensile Strength Perpendicular to the Surface the Tape in Dry Conditions δ min. 15 kPa - EN 13162:2012+A1:2015( EN 1607 )
Tensile Strength Perpendicular to the Surface Tape in Humid Conditions δ min. 10 kPa - EN 13162:2012+A1:2015( EN 1607 )
Certificarea de conformitate CE (CE) No. 1020 - CPR - 010035265
THICKNESSLENGHTWIDTHTHERMAL CONDUCTIVITYTHERMAL RESISTANCE
(mm) (mm) λD [W/mK] R [m2K/W]
506006000,0351,35
606006000,0351,62
806006000,0352,16
1006006000,0352,70
1206006000,0353,24
1406006000,0353,82
1506006000,0354,00
2006006000,0354,55